The most important flammability classification in the computer, electrical and electronics industries worldwide is the rating according to Underwriters Laboratories Inc., U.S.A., pursuant to UL 94. Expanded on our specially designed Uni-Grid equipment, using .040 thick, 3000 series aluminum. This can significantly reduce both your cost and the time required for evaluation. UL-94 UL 94 is used to measure burning rate and characteristics based on standard samples. It is specifically for testing the flammability of plastic parts used in devices and appliances. Description: specifies UL 94 HF-1 filter media flame rating, minimum 80% dust arrestance, and UL 900 Class 2 framed filter fire rating. Highly resistant to solvents, chemicals, temperature and . 94 HF-1, -2, HBF. Two UL 94 ratings that code officials commonly run across are HB and V (V-0, Produced in durable reticulated foam to ensure uniform pore size and consistent performance, our UL94 air, dust and engine filter foams are used in an array of industrial and domestic environments. which respectively are horizontal flammability test and vertical flammability test. Resistance to petroleum base oils is not required UL 94, the Standard for Safety of Flammability of Plastic Materials for Parts in Devices and Appliances testing, is a plastics flammability standard released by Underwriters Laboratories of the United States. 6. Closed Cell EPDM Listed (UL 94: HF-1) Pass (FMVSS-302) Pass (FAR 25.853) Pass (ASTM D5132) DENSITY. Test procedure A total of 10 specimens (2 sets) are tested per thickness. Precaution, Pretection and Safety, all in FireTC . UL Vertical Tray: This test is performed to check flame resistance of power and communication cables used in trays. These small-scale tests measure the propensity of a material to extinguish or spread flames once it becomes ignited. NITOFLON No.903UL/No.9030UL. K-FLEX K 41-PA K-FLEX K-TEK SELECTOR GUIDE Msds. The 94HB test describes the Horizontal Burn method. You take a sheet 200mm X 50m and form a cone with it to perform the flame test as shown in the figure. Vertical flame propagation test Y Y- UL94 is a test for Flammability of Plastic Materials for Parts in Devices and Appliances. Conover, NC 28613 . ASTM D1056 Classification: 2B1 (C1,F1,M) Compression Resistance @ 25%: 2-4 psi. UL94 covers tests for flammability of polymeric materials used for parts in devices and appliances, it is applied to measure and describe the . Thus, a propagation speed can be measured. Clamp Design for Vertical Flame Test Specified in UL 94 6. For material with thickness less than 3mm the burning rate should not exceed 75mm per minute. UL 94 is a small scale standard vertical flame test. This is the highest and most flame retardant level of the UL 94 ratings. Cases like this are what UL 94VTM is used for. . decorative objects. The test is similar to the CSA FT4 flammability test, but not as stringent. ARESTO is a fire-retardant, flexible polyester polyurethane foam which has been designed for applications where flammability characteristics must meet standards such as Department of Transportation Motor Vehicle Safety Standards #302 (FMVSS-302) or Underwriters Laboratories Classification UL 94 HF-1. 017, and Fire Hazard Testing - Part 11-10: Test Flames - 50 W Horizontal and Vertical Flame Test methods, IEC 60695-11-10; Interpretation of Paragraph 7.1.3 of UL 94 for Testing Thicknesses Less Than 3.0 mm 7. Vertical Testing of Thin Materials (VTM0, VTM1, VTM2) Indicate the choice of test medium (Oil) 10. Fire Retardant Foam. A UL 94-V0 classification was achieved for the network with oligophosphonate and aromatic curing agent. Industrial Applications UL 94 HF-1 UL 94 V-0 UL 94 V-1 UL 50 / UL 48 / UL 508 . Flame Classification. (or UL 746C), or no flame rating required if part mounted on . [1] The standard determines the material's tendency to either extinguish or spread the flame once the specimen has been ignited. UL 94 flammability testing ranks plastics according to their ability to ward off ignition, remain consistent in high temperatures, and produce flammable plastic drippings. Filtration Performance Data: Polyester air filters have been specially designed for equipment where space is limited. They provide high-level performance and flame retardancy even in the harshest conditions. In addition to the UL 94 HF-1 compliant foam, most of our XLPE and Zotefoams materials pass the FMVSS-302 motor vehicle specification. HF-1, HF-2, HBF. EC-100 Series. 2. - ASTM E84 25/50 rated (to 1 in) - tested according to UL 723. 3. UL 1666: This is also called a Riser Cable test. UL 94 also describes a method in which the test flame is applied for up to five applications in testing for a 5VA or 5VB classification. Home / Technical Information / UL Recognition and Flammability Ratings / UL94 V-0, V-1, & V-2 Flammability Standard Specimen Length 125 mm (5 in) x Width 13 mm (0.5 in) x Thickness [typically 0.7 mm (1/32 in) or 1.5 mm (1/16 in) or 3.0 mm (1/8 in)]. ARMACELL LLC 1004 Keisler Rd. Compression Set @ 50%: 30% max. Tensile : . Depending on the orientation of the sample and the type or desired rating, various data points are measured including burn rate, afterglow, afterflame, and dripping. Our broad selection hoses with UL 94V-0 flammability rating are available in a variety of wall thicknesses, diameters from 1" to 48" and lengths up to 50 feet. HB: The lowest fire rating in the UL94 flammability standard. UL 94 Fire Resistant Filter Foam Our RFR Series safeguards sensitive electronics and equipment from harmful contaminants. Product . The prevailing flammability test for rubber materials is UL 94. Difference in test methods and criteria Quadrafoam and Quadrafoam II are open cell polyurethane foams specially coated to provide a UL 94 HF-1 flame safety rating, fungus resistance, and UV radiation . Products of the Nitto Denko EC-100 Series which have obtained UL-94 HF-1 certification are composed of a flexible foam sealing material consisting of EPDM rubber foam with a semi-closed cell structure mixed with a flame retarder. For more information and assistance with ASTM D6576 and closed cell silicone sponge, please call Stockwell Elastomerics at 215-335-3005 or complete a contact form for assistance. Flame Name. Final Classification When Testing UL 94V or 5V in UL 94 (PROPOSAL) 4. Thickness must be reported when a rating is given. Clarification for HB Test in UL 94 5. Frame / Assembly: Yes. The second program measures the ignition resistance of the plastic to electrical ignition sources. UL 94 is a widely-used plastics flammability test created by the Underwriters Laboratories (UL) that measures how a plastic part burns and how well it prevents flames. UL 746A, Section 21 - AC Dielectric Breakdown Voltage and Strength. FLAMMABILITY UL 94 V (50 W, 20 mm Vertical) Objectives UL94 is the most widely used flame retardant performance evaluation standard for plastic materials, with a total of 12 classifications: HB, V-0, V-1, V-2, 5VA, 5VB, VTM-0, VTM-1, VTM-2, HBF , HF-1, HF-2. UL 94 Foam Material Testing (HBF/HF-1/HF-2): Inclusion of Density Value in Section 12 . UL 94 HB Rating A material having a thickness between 3 and 13mm will be classified as a HB material if it does not have a burning rate exceeding 40mm per minute. HBF; HF-1 and HF-2 Table II - EMI Gasket (Ratings as of 4/1/00) Gasket Flame Rating Ni/Cu Plated ElectroFab V-0 Ag Plated Electrofab V-0 -Horizontal Burning Foamed Material Test(HBF, HF-1, HF-2)-Vertical Burning Test(5VA, 5VB) . UL 94: Test for Flammability of Plastic Materials for Parts in Devices and Appliances. D4985 HF-1, -2, HBF; C22.2 No. 1) HB Class: Horizontal Burning Test. Flammability: 25/50 Rated (up to 2") - ASTM E84 Listed - UL 94 HF-1, V-0, 5VA Pass - FMVSS-302 Pass - FAR 25.853. Many thin materials that will not burn but will shrink to the clamp and need VTM testing. V-1. Flammability Class - UL 94 HF-1 Applications for these noise reduction barriers typically include power generation, medical equipment, and on and off highway vehicles. It is performed on cables that are used in vertical runs in . It is a more stringent test than UL 94 V -0 in several ways. Smoke Developed Index: 50. . printed circuit board. UL 94 VW-1 flame test is used to evaluate the ability of materials to extinguish after being ignited. 30% Max (ASTM D1056) Documents Marketing. HF 1 rating was not possible even at 7.5% EDA-DOPO . Fluoroplastic Adhesive Tape NITOFLON No.903UL/No.9030UL. UL 94 -5V is a test standard for materials which are already classified as UL 94 V -0. The five ratings are: HB, V-2, V-1, V-0, and 5V. The UL 1061 is mainly used appliance wiring. K-FLEX K 41-PA_MSDS_USA_425181.pdf . Very thin films. The top rating is "V0." Our products Apec high-heat polycarbonate, Bayblend (PC+ABS; PC+ASA blend), Makroblend (PC+PBT; PC+PET blend), Makrolon polycarbonate score different flame . Whatever your application, Flexaust has the hose material, thickness, and length you need for reliable fire resistance. The results of most UL 94 flammability tests are not applicable to materials whose thickness exceeds 13.0 mm, or whose surface area exceeds 1m2. . Classification: General Business Use . UL94 Underwriters Laboratories . - UL 94 (flammability test) UL-94 (flammability test UL-94) UL-94 (flammability test) Class H electrical insulating adhesive tape using fluoroplastic film. Type 2 Closed Cell rubber. HB 3mm 75 mm/min; V230 . ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. For finished goods, frequently the UL Recognition of component materials can eliminate the need for some tests on the final product. ISO 9772 . Four sets of 5 specimens with nominal dimensions 150mm x 50mm. Clamp Design for Vertical Flame Test Specified in UL 94 6. 0.17 HF-1, -2, HBF. This guideline. BPT Test Revision in UL 746A Polymer Variation Program (Table 9.2) (PROPOSAL) 9. UL 94 Underwriters Laboratories UL94 . This guideline specifies UL 94 HF-1 filter media flame safety rating, minimum 80% dust arrestance, UL 900 Classification marked frames, and framed air filter requirements. ASTM E162 Class B(26-75) Silicone Rubber Selections. For material with thickness less than 3mm the burning rate should not exceed 75mm per minute. Construction: Panel Filter. 1. UL 94 Flame Overview Information Sheet UL Flotation Information Sheet . The testing is conducted on bar and plaque specimens using a larger flame height than in vertical testing (125mm vs 20mm). UL94 Foamed Material Horizontal Burning Test for Classifying Materials HBF, HF-1 or HF-2. Classification UL 94: HB, HB 40 et HB75 or HBF, HF-1 and HF-2 for the foam This test consists in putting the material horizontally under a 500W flame to assess its fire behavior for the horizontal propagation. Standards for flammability UL 94 5V UL 94 On request: (IEC) DIN EN 60695-11-20 or equivalent standards Uni-Grid expanded aluminum is approximately 85% open to lower resistance. 1 psi max Maximum Thickness 1-1/8" 50% Compression Set 5% max Automotive Specs GMW 15473 Class 1 Type 1, Chrysler MSAY 430 Type 1, Toyota TSK 6505G Class 2A, Ford WSB-M3G212A Tensile Strength 20 psi min . UL 94 HB Rating A material having a thickness between 3 and 13mm will be classified as a HB material if it does not have a burning rate exceeding 40 mm per minute. Clarification for HB Test in UL 94 5. Sealant containing a flame retarder is UL-94 HF-1 certified. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. Sample size is 12.7mm by 127mm, with the thickness varying from 0.8mm to 3.2mm. The flammability classification required of a material is dependent upon the equipment or device involved and the particular use of the material. Flammability Characteristics: -Meets the requirements of S4.3 of Federal Motor Vehicle Safety Standard No.302.1 -Meets UL 94 classification HF-1 @ 0.062 inch minimum thickness.